LoRaWAN Zone Leak Detection Sensor (ZLD)
An industrial-grade zone leak detection system built to identify liquid accumulation across extensive linear structural zones. Using an advanced flexible sensing cable loop alongside multi-environmental sensors tracking heat and humidity metrics, it serves as an all-in-one safeguarding layout for data centers, structural raised floor basements, and critical industrial corridors.
Key Highlights
- Expansive Linear Fluid Tracking: Utilizes a flexible sensing cable to monitor large perimeters and long utility pipes simultaneously for uniform coverage.
- Integrated Climate Analytics: Outfitted with built-in high-performance sensors evaluating relative humidity and temperature points.
- Heavy-Duty Waterproof Enclosure: Features an IP67-rated enclosure engineered to survive submerged exposures, dust buildup, and prolonged UV contact.
- Optimized 10-Year Efficiency: Managed via ultra-low-power radio telemetry to yield massive multi-year service lifespans from a single cell replacement.
- Robust Data Recovery Architecture: Stores 2,800 internal operational events safely on-device, automatically pushing records post-outage to prevent telemetry loss.
Product Overview
The ZLD system functions as a high-performance zone leak detection solution designed to catch liquid aggregation across extensive, complex linear pathways rather than single spots. It utilizes a highly flexible, heavy-duty conductive sensing rope cable matrix that can wrap easily around server room perimeters, under raised floors, or along long utility pipelines. The architecture integrates premium environmental components to constantly run precise diagnostics on ambient temperature variations and microclimate humidity limits. Engineered inside a complete IP67 weather-sealed polymer enclosure, the node resists heavy dust saturation, direct water spray, and continuous moisture pooling. Built with smart peer-to-peer protocols, it supports direct connection rules to issue an immediate shutoff command to remote valve gates without waiting for gateway or cloud internet responses.
Key Features & Capabilities
Enterprise-grade technology designed for mission-critical operations
Flexible Linear Rope Sensing
Equipped with a standard 3-meter highly conductive wire rope composed of premium PE and steel wire, customizable up to several hundred meters for maximum zone routing.
Wide-Spectrum Environmental Trapping
Maintains highly precise microclimate tracing capabilities across structural limits spanning -30°C up to +70°C with 0.1°C resolution values.
NFC Wireless Parameterization
Integrates an operational near-field reader for quick adjustments, configuration changes, firmware handshakes, and diagnostic logs right on a smartphone app.
Direct Peer Valve Manipulation
Equipped with direct D2D smart automation layer features to trigger immediate shutoff commands directly to localized flow gates without relying on intermediate internet networks.
Universal Open Telemetry Linkages
Maintains native Class A operational design for simple setup over third-party network stacks, gateways, and centralized SCADA platforms.
Technical Specifications
Key technical details and performance specifications
| Specification | Details |
|---|---|
| Product Type | LoRaWAN Zone Leak Detection Sensor |
| Wireless Technology | LoRaWAN® and Device-to-Device (D2D) Protocol |
| Frequency Bands | CN470 / IN865 / RU864 / EU868 / US915 / AU915 / KR920 / AS923-1&2&3&4 |
| RF Transmission Power | 16dBm (868 MHz) / 20dBm (915 MHz) / 19dBm (470 MHz) |
| Receiver Sensitivity | -137dBm @300bps |
| Leakage Rope Type | Zone detection via specialized conductive fluid cable rope |
| Trigger Height Threshold | When liquid level reaches 5mm on the sensing cable layer |
| Standard Rope Length | 3 meters (Customizable up to hundred meters) |
| Temperature Measurement Range | -30°C to +70°C |
| Temperature Measurement Accuracy | +/- 0.3°C (from 0°C to +70°C); +/- 0.6°C (from -30°C to 0°C) |
| Humidity Measurement Range | 0% to 100% RH (Non-condensing) |
| Humidity Measurement Accuracy | +/- 3% RH within 10% to 90% RH bands; +/- 5% RH for remaining bands |
| Measurement Resolution | 0.1°C Temperature / 0.5% RH Humidity |
| Local Historical Cache | Up to 2,800 records stored locally for automated data retransmission |
| Default Power Configuration | 1 x 4000 mAh ER18505 Li-SOCl2 Battery (Dual battery holder supporting up to 8000 mAh optional) |
| Battery Operational Life | Over 10 Years (SF7, 10 min reporting intervals + 24 triggers daily) |
| Ingress Protection Rating | IP67 Rated |
| Enclosure Properties | Flame Retardant White ABS + Polycarbonate (Transceiver) |
| Sensing Cable Properties | PE + Steel Wire (High strength, flexible Yellow & Black color layout) |
| Physical Dimensions | 105.6 x 85.3 x 27 mm (4.16 x 3.36 x 1.06 inches) |
| Mounting Options | Transceiver: Wall screw mounting, 3M tape adhesive, or cable-ties. Sensing Rope: 3M tape clips or cable-tie positioning. |
| Compliance Certifications | CE, FCC, ISED, RCM, Telec, ICASA, RoHS |