Short answer: an RFID printer prints a normal thermal label and writes data into the RFID inlay inside it, in one pass. It then checks the write. If a tag fails, the printer prints "VOID" over that label and tries again on the next one. To run one at scale you need four things right: the label stock and inlay position, the EPC encoding scheme, the void and retry settings, and a clean data feed from your ERP or WMS.
This guide covers how print-and-encode works, how to choose label stock, how EPC encoding works, what causes voided labels, and what to ask before you buy.
What does an RFID printer do?
It does three jobs on every label:
- Prints text, barcodes and logos, like any thermal transfer or direct thermal printer.
- Encodes the RFID inlay with an EPC (Electronic Product Code) and, if needed, user memory, using a built-in UHF encoder.
- Verifies the write. Labels that fail are voided and the same data is retried on fresh labels.
Zebra's ZPL reference describes the void step. When a label fails to program or the transponder can't be found, the printer ejects it, prints VOID across it, and retries the same data and format. The retry count is set with the ^RS command, from 1 to 10 labels, with 3 as the default (Zebra, ZPL programming guide, ^RS). If the error persists, the printer can drop that format and move on (the default), pause, or go into error mode until someone clears it.
The flow matters for audits. A voided label never reaches an asset, and the next good label carries the same data, so your register doesn't get gaps or duplicates.
When should you print in-house instead of buying pre-encoded labels?
Both work. The choice comes down to how variable your data is.
| Situation | Better option | Why |
|---|---|---|
| Asset tagging with your own asset codes | In-house RFID printer | Each label carries a unique asset number, printed and encoded on demand |
| Warehouse labels created at goods receipt | In-house RFID printer | Data comes from the WMS at the moment of receipt |
| Retail item tags with fixed GTINs and serials | Pre-encoded from a converter, or in-house for top-ups | High volumes are cheaper from the converter; printers cover exceptions |
| On-metal tags for tools and equipment | Printer that supports on-metal media, or pre-encoded | On-metal tags are thicker and need supported media |
| Re-labelling after damage | In-house | Re-issue the same EPC from the register |
Many projects need both: a bulk order of pre-encoded tags for the first tagging drive, then a printer on site for new assets and replacements. See our asset tagging guide for the tagging drive itself.
How do you choose RFID label stock?
The label is half the system. Three checks:
- Inlay performance for your surface. Auburn University's RFID Lab runs the ARC programme, started in 2009. End users define a performance specification for their use case and packaging. The lab benchmarks inlays and lists the approved ones against each spec (Auburn University RFID Lab, ARC). Even if you don't use ARC, copy the method: test candidate inlays on your real cartons, totes or asset surfaces.
- Inlay position on the label. The printer can only encode inlays inside its programming zone. Zebra lists low yields, with too many tags voided per roll, as a symptom of transponders outside the area the printer can program consistently (Zebra, ZT411/ZT421 user guide, RFID issues). Ask the label converter for the printer maker's placement specification.
- Protocol. The same Zebra guide notes its printers support only Gen 2 RFID labels. Older or non-Gen 2 inlays will be voided.
For metal assets, use on-metal tags and a printer that supports them, or buy them pre-encoded. Our UHF labels page lists common formats.
What should you encode on the tag?
Use a GS1 EPC scheme unless you have a strong reason not to. GS1's EPC Tag Data Standard defines the EPC and the memory contents of Gen 2 tags. The table uses release 1.10 (GS1, EPC Tag Data Standard 1.10, March 2017). GS1's reference site was under maintenance when we checked on 21 October 2026, so confirm the current release with your label converter. Points that trip people up:
| Item | What the standard says | What it means for you |
|---|---|---|
| SGTIN-96 serial | Numeric only, no leading zeros, up to 274,877,906,943 | Fine for running numbers; not for alphanumeric serials |
| SGTIN-198 serial | Up to 20 alphanumeric characters | Use when your serials contain letters |
| Filter value 1 | Point-of-sale trade item | Retail items |
| Filter value 2 | Full case for transport | Cartons |
| Filter value 6 | Unit load | Pallets and similar load carriers |
| Filter value 0 | All others | Use only when nothing else fits |
Fixed assets usually use GIAI and returnable containers GRAI. Our GS1 EPC standards guide explains each scheme. Decide the scheme before you buy labels, because it drives your label software templates and your ERP fields.
Why does an RFID printer void labels?
From Zebra's troubleshooting list, the usual causes are:
- Calibration. If the printer voids every label, it usually isn't calibrated for that media. Recalibrate after every media change.
- Inlay position. Tags sit outside the programmable area, or the programming position in the label design software is wrong.
- Power levels. Read and write power set too high or too low causes inconsistent encoding.
- Interference. Fixed RFID readers nearby can disturb encoding. Zebra advises moving the printer away and keeping the media door closed while it encodes.
- Software overriding the printer. Label design software settings can override printer settings, so the two must match.
- Firmware. Outdated printer or reader firmware.
Track the void rate per roll. A rising rate is an early warning of a stock, placement or settings problem.
What should finance track once the printer is running?
The printer is a one-time cost. Label stock and voided labels are the running cost, so track three numbers every month:
| Metric | How to work it out | Why it matters |
|---|---|---|
| Void rate | Voided labels ÷ total labels fed | A rising rate points to stock, placement or settings |
| Cost per good label | (Label stock + ribbon) ÷ good labels | Voids push this up even when the roll price stays the same |
| Re-issue count | Labels printed again for the same asset | Shows damage, poor surface choice or process gaps |
A worked example, with round numbers only to show the maths: if you feed 10,000 labels and 300 are voided, the void rate is 3%. You paid for 10,000 labels but got 9,700 usable ones, so each good label costs about 3% more than the roll price suggests. Get real prices from your converter's quote and plug them in.
Do RFID printers need radio approval in India?
The encoder is a UHF RFID interrogator, so the 865 to 868 MHz rules apply. Under G.S.R. 853(E) of 10 December 2021, RFID interrogators may use up to 2 W e.r.p., but only in four channels centred at 865.7, 866.3, 866.9 and 867.5 MHz (Gazette of India, G.S.R. 853(E)). An RFID printer's encoder works at very short range, but it must still be the India region variant. Ask for the model's India configuration and approval paperwork.
How does the printer connect to SAP or a WMS?
Keep the data flow simple:
- The ERP or WMS creates the record: asset number, GTIN and serial, or SSCC.
- Label software or middleware turns it into a print job with the EPC.
- The printer prints, encodes and verifies.
- The result (good, or voided and retried) goes back to the system, so the register records the EPC that was actually written.
Step 4 is the one projects skip, and it's the one auditors ask about. Zebra printers can send an error message to the host for each failed encode (the ^SX and ^SQ commands, with condition type V for RFID errors), so your middleware can log every void against the record (Zebra, ^RS). Our SAP and WMS integration guide covers the read side.
Is demand for RFID labels growing?
Supply is huge, even if the yearly count moves around. The RAIN Alliance reported 52.8 billion passive UHF tag chips shipped in 2024, up 54% over two years, from five chip makers (RAIN Alliance, February 2025). Its April 2026 report put 2025 at 42.7 billion, from four reporting chip makers, so the two years aren't a like-for-like comparison (RAIN Alliance, April 2026). For a buyer, either number means wide label supply and plenty of converters to compare. Our retail RFID post covers where that volume goes.
Questions to ask before you buy an RFID printer
- Which inlays and label sizes are supported, and what is the inlay placement specification?
- Is the encoder the India region variant for 865 to 867 MHz, and is there approval paperwork?
- How are void retries and the error action set, and can the result be sent back to our system?
- Which label design software and drivers support EPC encoding with our GS1 scheme?
- Does the model support on-metal media if we tag equipment?
- What void rate do you expect with our label stock? Will you run a test roll?
- Who calibrates the printer after media changes, and is that covered in the AMC?
- How is firmware updated for the printer and its RFID reader?
FAQs
Can a normal barcode printer encode RFID? No. It needs a built-in RFID encoder. Some industrial models can be upgraded with one, so check the model.
What does VOID mean on an RFID label? The printer could not write or verify the tag, so it marked the label unusable and retried the same data on the next label.
Which EPC scheme should I use for fixed assets? GS1 GIAI is the usual choice for fixed assets. Use SGTIN for trade items and GRAI for returnable containers.
How many retries should I allow? Zebra's default is 3, with a range of 1 to 10. Keep it low and fix the cause if voids rise.
Do I need special labels? Yes. Use RFID labels whose inlay suits your surface and sits in the printer's programming zone. Test a roll first.
Need help choosing a printer and label stock? See our RFID printers, the RFID and AIDC solutions page, or contact us.
Sources
- Zebra Technologies, ZPL Programming Guide, ^RS Set Up RFID Parameters: page
- Zebra Technologies, ZT411 and ZT421 User Guide, RFID Issues: page
- GS1, EPC Tag Data Standard, Release 1.10, ratified March 2017: PDF
- Auburn University RFID Lab, About ARC: page
- Gazette of India, G.S.R. 853(E), 865-868 MHz Short Range Devices (Exemption from Licence) Rules, 2021: PDF
- RAIN Alliance, 52.8bn RAIN tag chips shipped globally in 2024, February 2025: release
- RAIN Alliance, 42.7 billion tag chip shipments in 2025, April 2026: release