Short answer: data centre switching today is mostly built as a leaf-spine fabric. Servers plug into leaf (top-of-rack) switches, every leaf connects to every spine, and traffic between any two racks crosses the same number of hops. It handles server-to-server traffic far better than the old core, aggregation and access design. For a growing enterprise server room, 25G to the server and 100G uplinks is a sensible default, with oversubscription planned at the leaf.
This guide covers why leaf-spine replaced three-tier designs, how to size oversubscription, 25G and 100G choices, when a small site doesn't need a fabric, cabling, cost lines and questions to ask a vendor.
Why did data centres move away from three-tier networks?
The classic design had three layers: access switches in racks, aggregation switches above them, and a core. It worked when most traffic went north-south, from users to servers and back.
That changed. IETF RFC 7938, written by engineers from Facebook and Arista, notes that many large data centres now carry significant server-to-server, or east-west, traffic. Scaling tree topologies to meet that demand gets too expensive or impossible, partly because there aren't core boxes with enough ports (RFC 7938, August 2016).
Virtualisation, hyperconverged storage, microservices, backup and now AI training all push traffic sideways between racks. A design that funnels everything through a pair of core switches becomes the bottleneck.
How does a leaf-spine fabric work?
A leaf-spine fabric is a folded Clos network:
- Leaf switches sit in or near each rack. Servers, storage and firewalls connect to leaves.
- Spine switches connect only to leaves. Nothing else plugs into a spine.
- Every leaf connects to every spine, at the same speed.
RFC 7938 makes two points that matter for design. The number of equal-cost paths between any two leaves equals the number of spines, so traffic is shared across all of them using ECMP. And oversubscription is introduced at the leaf, so it's kept to one layer and applications don't have to deal with several bandwidth pools.
The approach scales a long way. Google's SIGCOMM 2015 paper describes five generations of Clos fabrics built from merchant switch silicon, growing capacity 100 times over ten years to more than 1 Pbps of bisection bandwidth (Google, Jupiter Rising, SIGCOMM 2015). Enterprise fabrics are far smaller, but the same design rules apply.
What is oversubscription and how much is acceptable?
Oversubscription on a leaf is server-facing bandwidth divided by spine-facing bandwidth. CommScope's fabric design guide gives a worked example: a leaf with 48 x 10G server ports needs 480G of fabric bandwidth to be non-blocking. With four spines and one 40G link to each, the leaf has 160G up, which is 3:1 (CommScope, Fabric Networks design guide).
The guide puts the trade-off plainly. If the ratio is too high, applications suffer. If it's kept very low, fewer servers fit on the fabric for the same spend. It also notes that storage traffic that depends on a non-blocking network is hit hardest by contention.
Practical guidance:
| Workload | Starting point for leaf oversubscription |
|---|---|
| General virtualisation, web and app servers | 2:1 to 3:1 is often workable |
| Hyperconverged or IP storage on the same fabric | Aim lower, around 1.5:1 or better |
| AI and HPC clusters | Plan for 1:1 (non-blocking) on the GPU fabric |
These are design starting points, not rules. Measure your own traffic. Most switches can report per-port utilisation, and a few weeks of data will tell you more than any rule of thumb.
25G, 100G or more: which speeds should you choose?
IEEE approved 802.3by, the 25 Gb/s Ethernet standard, on 30 June 2016 (IEEE P802.3by Task Force). Many new designs pair 25G server ports with 100G uplinks to spines. The reason is mostly arithmetic: four 25G lanes make one 100G port, so leaf and spine optics line up neatly.
| Layer | Common choice for new builds | When to go higher |
|---|---|---|
| Server to leaf | 25G (often dual-homed) | 100G for storage nodes, GPU servers |
| Leaf to spine | 100G | 400G for large fabrics or AI clusters |
| Firewall, WAN, internet edge | 10G to 100G, on border leaves | Based on internet and DC-to-DC links |
Two tips. First, check what your servers' network cards and the hypervisor support before buying leaf ports. Second, buy spine ports with a speed upgrade path; spines are the hardest part to replace later.
When don't you need a leaf-spine fabric?
A small server room with two or three racks usually doesn't need one. A pair of switches running as a collapsed core, with redundant links to each server, is simpler and cheaper.
Consider leaf-spine when:
- you have, or expect, more racks than a single switch pair can serve with good redundancy
- east-west traffic is high: HCI, storage replication, backup, analytics or AI
- you want to grow by adding racks without redesigning the network
- you run a colocation cage or a private cloud that will expand
Our guide to network switches covers access, distribution and core switching for campuses and smaller sites, and data centre design tiers covers power and redundancy.
What about routing, overlays and cabling?
Routing. RFC 7938 describes using BGP as the only routing protocol in large fabrics, because it's simpler to run and fails over predictably. Many enterprise fabrics now use a routed underlay with BGP, and an overlay such as VXLAN with EVPN to stretch Layer 2 where applications need it.
Cabling. Every leaf connects to every spine, so the number of links grows quickly. CommScope recommends a cross-connect in the main distribution area for any-to-any patching, and notes cross-connects are mandatory under EN 50600 in Europe. MPO trunk cabling keeps fibre counts manageable. Our structured cabling guide covers standards and rack layout.
Automation. With dozens of identical switches, manual configuration invites mistakes. Use templates or the vendor's fabric manager, and keep configurations in version control.
What does a leaf-spine fabric cost?
Prices depend on brand, port speed and licensing, and there's no reliable public Indian price list. Ask for each line separately:
| Cost line | What drives it |
|---|---|
| Leaf switches | Number of racks, server port speed, dual-homing |
| Spine switches | Number of leaves, uplink speed, growth headroom |
| Optics and cables | Distances, 100G or 400G, DAC vs fibre |
| Licences | Routing, EVPN, automation, telemetry features |
| Fabric management software | Per switch or per fabric, term or perpetual |
| Cabling and cross-connects | Fibre counts, MPO trunks, patch panels |
| Support | Per switch per year, response time |
Optics add up quickly across dozens of links, so price them with the switches, not later. Check whether the vendor allows third-party optics, and what that does to support.
Questions to ask a data centre switching vendor
- What oversubscription does your design give per leaf, and how did you size it from our traffic?
- How many spines, and can we add more without downtime?
- What happens when a spine or a leaf fails? How long does traffic take to reroute?
- Which routing and overlay design do you propose, and why?
- Which features need extra licences, now and at renewal?
- Do you support third-party optics?
- How is the fabric configured and monitored: templates, controller, or box by box?
- What's the support cost per year and the replacement time for a failed switch in our city?
FAQs
What is a leaf-spine network? A two-layer data centre network where every leaf switch connects to every spine switch, so any rack reaches any other rack in the same number of hops.
What is a good oversubscription ratio? It depends on the workload. 2:1 to 3:1 is common for general servers; storage and AI fabrics need much lower, down to 1:1.
Is 25G worth it over 10G for servers? For new builds, usually yes. Four 25G lanes make a 100G uplink, which keeps the fabric design simple.
Do small server rooms need leaf-spine? Usually not. Two or three racks run well on a redundant switch pair.
What does ECMP do in a fabric? It spreads traffic across equal-cost paths. In a leaf-spine fabric, the number of paths equals the number of spines.
Planning a new server room or data centre network? See our data centre switching and fabric products, data centre infrastructure solutions, or contact us.
Sources
- IETF RFC 7938, Use of BGP for Routing in Large-Scale Data Centers, August 2016: RFC Editor
- IEEE P802.3by 25 Gb/s Ethernet Task Force, approval of IEEE Std 802.3by-2016 on 30 June 2016: IEEE 802.3
- Singh et al., Jupiter Rising: A Decade of Clos Topologies and Centralized Control in Google's Datacenter Network, SIGCOMM 2015: Google Research
- CommScope, Fabric Networks design guide: designing your network for the future, from 10G through 400G: PDF